Garage Door:  Automatic Door Reverse Feature has been disabled.
Qualified garage door installer should make appropriate corrections for safety.


Under-Floor Crawlspace Plumbing:   Open drain line; Sink is draining to crawl space area; Replacement of drain / waste, vent system recommended.


Deck Framing:  Any beams that are attached to the sides of posts / columns should be secured with appropriately sized through bolts for safety. 

 

 

 

 

Siding / Finish Grade Contact:  Ideally the slope should fall away from the foundation at a minimum of 1/2"  per foot and extend at least 10' from the foundation.  The grade slopes toward the foundation and is less than 6" from siding / framing.  Provide clearance of 6" between earth and siding and proper slope from foundation.


Attic Crawl Space:  Bathroom vent terminates at interior of attic;  Repair duct so that moisture is expelled to exterior of house.


Electrical Safety Hazard:  Live, exposed wiring near baseboard; Have licensed Electrician make appropriate repairs.


Electrical Panel:  1.  Incompatible breaker / conductor size at water heater circuit (40 amp breaker / #10 branch wiring).  2.  Several of the breakers are types that are not listed as acceptable types for use with this panel: only compatible breakers should be used.  Licensed Electrician should make appropriate repairs.


Roof:  Missing hip cap shingles were observed at corners.  Signs of previous leakage were observed.  Recommend repair.

 

Our Goal is to Provide the Most Accurate Home Inspection available with Thorough, Complete Reporting and Excellent Service.    

Toll Free:  1-866-722-7836     Local  Phone / Fax:  541-764-8956 
email:  inspector@pbhomeinspections.com
PO Box 624  Gleneden Beach, OR 97388

Serving:  Lincoln County-
Newport, South Beach, Seal Rock, Waldport, Yachats, Depoe Bay,
Otter Rock, Toledo, Siletz, Gleneden Beach, Lincoln City
South Tillamook County-  Tillamook, Pacific City, Neskowin